23
Enhancements
Release L.10.06 Enhancements
The show sflow destination command includes information about the management-station’s destina-
tion address, receiver port, and owner.
Figure 4. Example of Viewing sFlow Destination Information
Note the following details:
■ Destination Address remains blank unless it has been configured on the switch via SNMP.
■ Datagrams Sent shows the number of datagrams sent by the switch agent to the manage-
ment station since the switch agent was last enabled.
■ Timeout displays the number of seconds remaining before the switch agent will automati-
cally disable sFlow (this is set by the management station and decrements with time).
■ Max Datagram Size shows the currently set value (typically a default value, but this can
also be set by the management station).
The show sflow sampling-polling command displays information about sFlow sampling and polling on
the switch. You can specify a list or range of ports for which to view sampling information.
Figure 5. Example of Viewing sFlow Sampling and Polling Information
The show sflow all command combines the outputs of the preceding three show commands including
sFlow status information for all the ports on the switch.
ProCurve# show sflow destination
sflow Enabled
Datagrams Sent 221
Destination Address 10.0.10.41
Receiver Port 6343
Owner admin
Timeout (seconds) 333
Max Datagram Size 1400
Datagram Version Support 5
ProCurve# show sflow sampling-polling 1-5
sflow destination Enabled
Port | Sampling Dropped | Polling
Enabled Rate Header Samples | Enabled Interval
----- + ------- -------- ------ ---------- + ------- --------
1 | Yes 6500000 128 5671234 Yes 60
2 | No 50 128 0 Yes 300
3 | Yes 2000 100 24978 No 30
4 | Yes 200 100 4294967200 Yes 40
5 | Yes 20000 128 34 Yes 500