Specifications 155
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Server specifications
Specification Value
Dimensions
Rack model
Height
17.48 cm (6.88 in)
Depth
69.93 cm (27.53 in)
Width
48.34 cm (19.03 in)
Tower model
Height
47.04 cm (18.52 in)
Depth
73.96 cm (29.12 in)
Width
24.77 cm (9.75 in)
Weight
Weight (when lightly loaded)
Rack
25.00 kg (55.12 lbs)
Tower
30.00 kg (66.14 lbs)
Weight (maximum)
46.75 kg (103.06 lbs)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:

Table of Contents

Other manuals for HP ProLiant DL G6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL G6 and is the answer not in the manual?

HP ProLiant DL G6 Specifications

General IconGeneral
BrandHP
ModelProLiant DL G6
CategoryServer
LanguageEnglish

Related product manuals