window displays automatically when the CMC is first opened. You can also access it by
select SAN Status Page in the navigation pane.
◦ Identify the type of patch (urgent, recommended, informational) in the notifications window
so you can quickly determine the importance of the patch.
◦ Improve download capability by fixing the limitation of concurrent FTP connections. Increasing
the number of concurrent FTP connections ensures that you can obtain updates in a timely
manner and avoid connectivity issues.
• The Cancel button was not localized in the Spanish CMC.
• Added localized content for the Online Upgrades notifications window and for the FOM message
that displays on the Welcome window of the Management Group, Clusters, and Volumes wizard.
• The storage system may become unstable if, when entering a server address for email notification,
the address contains an invalid character (such as a forward or backward slash (/, \) or a colon
(:).
• The firmware version for both P410 RAID controllers in a P4900 G2 will not display correctly.
Application Aware Snapshot Manager
• Application-managed snapshots fail if vCenter is running under a domain account
SAN/iQ operating system
• Application-managed snapshots fail when CHAP is enabled.
• Application-managed snapshots fail when the host IQN contains uppercase letters.
• The storage server process may encounter a race condition and restart with the Storage Server
Down alarm during heavy system CPU load conditions.
• Performance issues could occur randomly on reads with large (2 TB or greater) volumes.
• The Maximum Transmission Unit (MTU) of the 10 GbE interfaces on a P4460sb G2 (P4800 server
blade) is incorrectly limited to 4,074 bytes. This patch will enable the MTU to be set to 9000
bytes.
• Some SNMP trap event severities do not match to corresponding CMC event severities.
• Notification emails and traps for email configuration events contain substituted text for "@x" in
the event message, where x is one of several alphanumeric characters.
• Updated Slot logs are generated successfully and support log bundles can now be emailed to HP
Support.
• Enable the configuration of additional network ports for SAN management traffic and keep
management traffic separate from SAN data traffic (for P4800 G2).
• The iSCSI session auto rebalancer may get stuck, causing data unavailability because iSCSI
sessions to a volume cannot be established. This may also result in a Storage Server Down alarm
if the storage server process restarts when encountering this condition.
• There was no time zone listed for GMT+01:00-BST-Europe/London.
Version 9.5—Patch Set 01
Centralized Management Console (CMC)
• Unable to log in to a management group after scheduling a snapshot on a volume that contains
special characters in its name.
• The Volume Failover/Failback wizard cannot be accessed due to a failed iSCSI session.