Procedure
1. From the System Utilities screen, select System Configuration > HPE Smart Array P824i-p MR
Gen10 > Main Menu > Configuration Management > View Global Spare Drives.
2. In the View Global Spare Drives screen, view the list of spare drives.
Making a JBOD
WARNING: Converting a drive to JBOD will permanently delete any data on the drive.
You can perform this task using either the Configuration Management screen or the Drive Management
screen.
Procedure
1. From the System Utilities screen, navigate to the Make JBOD menu option using either of the
following steps:
a. Select System Configuration > HPE Smart Array P824i-p MR Gen10 > Main Menu >
Configuration Management > Make JBOD.
b. In the Make JBOD screen, select the Unconfigured Good drive that you want to convert to JBOD.
c. Click OK.
d. Review and address any warning messages, as needed.
e. Click Confirm and Yes to proceed.
The Success screen appears to confirm that the operation completed successfully. For the drive
status change to reflect on the Drive Management screen, refresh the view.
a. Select System Configuration > HPE Smart Array P824i-p MR Gen10 > Main Menu > Drive
Management .
b. In the Drive Management screen, select the Unconfigured Good drive that you want to convert to
JBOD.
c. In the drive screen, select Make JBOD from the Operation drop-down menu.
d. Click Go.
The Success screen appears to confirm that the operation completed successfully. For the drive
status change to reflect on the Drive Management screen, refresh the view.
Making an Unconfigured Good drive
Procedure
1. From the System Utilities screen, select System Configuration > HPE Smart Array P824i-p MR
Gen10 > Main Menu > Drive Management .
2. In the Drive Management screen, select the JBOD drive that you want to convert to Unconfigured
Good.
3. In the drive screen, select Make Unconfigured Good from the Operation drop-down menu.
4. Click Go.
42 Configuration

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE Smart Array P824i-p MR Gen10 and is the answer not in the manual?

HPE Smart Array P824i-p MR Gen10 Specifications

General IconGeneral
BrandHPE
ModelSmart Array P824i-p MR Gen10
CategoryController
LanguageEnglish

Related product manuals