Energy pack specifications
Table 1: HPE Smart Storage Battery (96W)
Feature Description
Time required to recharge Smart Storage Battery 96 W: 2 hours (For maximum load of 24 devices)
Duration of Smart Storage Battery backup
150 seconds (maximum support)
The Smart Storage Battery provides a sufficient
duration to transfer the cached data from DDR
memory to flash memory, where the data remains
indefinitely or until a controller retrieves the data.
For more information, see the QuickSpecs document for the Smart Storage Battery.
Table 2: HPE Smart Storage Battery (12W)
Feature Description
Time required to recharge Smart Storage Battery 12 W: 1 hour (For maximum load of 3 devices)
Duration of Smart Storage Battery backup
150 seconds (maximum support)
The Smart Storage Battery provides a sufficient
duration to transfer the cached data from DDR
memory to flash memory, where the data remains
indefinitely or until a controller retrieves the data.
For more information, see the QuickSpecs document for the Smart Storage Battery.
Table 3: HPE Smart Storage Hybrid Capacitor
Feature Description
Time required to recharge capacitor pack Not applicable; charge is immediate
Duration of capacitor pack backup
60 seconds
The capacitor pack provides a sufficient duration to
transfer the cached data from DDR memory to
flash memory, where the data remains indefinitely
or until a controller retrieves the data.
The capacitor pack can be used in place of the 96 W Smart Storage Battery, but it is not supported on the
Apollo servers.
For more information, see the QuickSpecs document for the capacitor pack.
Energy pack options 61