• StoreOnce System server
• Rail kit
• Security bezel
• Two power cables
• Two network cables
2. Verify that you received the base storage enclosure contents.
• Storage enclosure
• Rail kit
• Four power cables
• SAS cables
◦ Two 0.5 m cables
◦ One 1 m cable. (The kit also includes a second, unused 1 m cable.)
◦ One 2 m cable
3. Record the iLO default network information from the label on top of the server.
iLO user name:________________________
iLO network name:_____________________
iLO password:_________________________
4. Install the optional PCIe cards, if necessary.
If the optional PCIe cards were ordered with the system, they have been preinstalled. If the cards
were ordered separately, install them now.
Figure 17: PCI slot numbers
a. Install the network cards starting in PCI slot 1 and then additional network cards in slots 2, 4, and
5 in that order.
b. Install the FC cards starting at PCI slot 5 and then additional FC cards in slots 4, 2, and 1 in that
order.
c. Verify that the correct SFP+ transceivers are fitted, if necessary.
For detailed installation instructions, see Install PCIe cards .
5. Install the server in the rack.
58 HPE StoreOnce 5250 and 5650 Systems