Powering down the Powering down the frameframe
ProcedureProcedure
1. If the frame to be powered down is part of a multiframe management ring with Image Streamer, see Powering down an HPE Synergy
frame that is part of a multiframe management ring with Image Streamer.
2. Locate the frame to be powered down .
3. Verify that the compute module UID LED is not flashing blue and that the compute module is in standby mode.
For more information, see the compute module user guide on the Hewlett Packard Enterprise website
(http://www.hpe.com/info/synergy-docshttp://www.hpe.com/info/synergy-docs).
4. Power down all compute modules .
5. Power down all appliance modules .
6. Verify that all LEDs indicate that all devices are powered off.
7. Disconnect all power cables from the power supplies in the frame.