EasyManua.ls Logo

HTC 800 RX - Resetting the Frequency Converter; Checking the Last Error Code

HTC 800 RX
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electronic error codes HTC 800 RX
38 2.0
7.2.1 Resetting the frequency converter
1. Turn off the machine by turning the start key to "Off"
2. Wait until the display goes out.
3. Reset the emergency stop switch.
4. Start the machine by turning the start key to "On".
Tip!
The machine will not start if the control ON/STOP is in the "ON" mode when
switching on the power.
7.2.2 Checking the last error code
For the buttons and knobs described here, see Figure7-1, page38
1. Press Enter. rEF is shown in the display.
2. Turn the knob counter-clockwise, until SUP is shown in the display.
3. Press Enter. FrH is shown in the display.
4. Turn the knob counter-clockwise, until LFt is shown in the display.
5. Press Enter. The last error code is shown in the display.
Figure 7-1. Enter button and knob - Schneider

Table of Contents

Related product manuals