58 |
PROGRAMMING
The following menu points are displayed and can be changed:
T1 ON
T1 HYSTERESIS
REL T1 DELAY
The parameters have the following meaning:
T1 ON
The switch-on temperature controls at which temperature the relay T1 should
be switched on.
Setting range: -40°C to +120°C
Factory setting: 23°C
T1 Hysterese
With the help of the hysteresis frequent switching of the relay T1 is prevented
when the measured temperature at the inner sensor T1 is equal or in the same
range as the set temperature T1 ON.
Setting range: 1 to 5°C
Factory settingen: C
REL T1 delay
The function REL T1 delay sets the switch-on delay for the relay T1.
This setting prevents frequent switching of the relay T1, if at slightly fl uctuating
temperatures, the setpoints T1 ON or T1 hysteresis have almost the same values.
Setting range: 0 to 60 sec.
Factory setting: 0 sec.
Behaviour of the relay T1
Abbreviations:
T1 measured temperature at the indoor sensor
T2 measured temperature at the outdoor sensor
T1 EIN setpoint of the switch-on temperature
Modes/ functions