Page #52 background image
SUN2000 (8KTL-28KTL)
User Manual
5 Electrical Connections
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Inverter
Model
Cable Type
Cross-sectional Area
(mm
2
)
External Cable Diameter (mm)
Range
Recommended
Value
Range
Recommended
Value
Range
Recommended
Value
SUN2000
-28KTL
cable
4-core
outdoor
cable
(3+PE)
ultraviolet-proof
measures on the
cable.
If the ground cable has been installed according to 5.1 Installing PGND Cables, you do not
have to connect the PE wire of the AC output power cable.
If a cable with a cross-sectional area of 4 mm
2
to 10 mm
2
is used, crimp a tubular cord end
terminal at the cable end before installing the cable.
An AC output connector has three parts: coupling nut, adapter, and cable gland, as shown in
Figure 5-5.
Figure 5-5 AC output connector
1. Coupling nut
2. Adapter
3. Cable gland
Procedure
Step 1 Remove the cable gland and the adapter from the AC output connector.
Step 2 Remove the insulation layer of the AC output cable of an appropriate length using a wire
stripper.

Table of Contents

Other manuals for Huawei SUN2000-20KTL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-20KTL and is the answer not in the manual?

Huawei SUN2000-20KTL Specifications

General IconGeneral
Max. efficiency98.6%
Rated AC output power20, 000 W
Max. apparent power22, 000 VA
No. of MPP trackers2
Max. input voltage1100 V
Protection degreeIP65
Max. DC Power30, 000 W
Start Voltage200 V
Nominal DC Voltage600 V
Max. Input Current per MPPT26 A
Nominal AC Grid Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading to 0.8 lagging
Total Harmonic Distortion (THD)<3%
DC Reverse-Polarity ProtectionYes
AC Overcurrent ProtectionYes
AC Short-Circuit ProtectionYes
DC Insulation Resistance DetectionYes
Residual Current MonitoringYes
AC Overvoltage ProtectionYes
DC SwitchYes
Cooling MethodNatural Convection
AC output voltage220 V / 380 V, 230 V / 400 V
MPPT operating voltage range200 V - 1000 V
Operating temperature range-25°C to +60°C
Relative Humidity0% - 100%
Operating AltitudeUp to 4000 m
Surge ProtectionType II DC & AC