2. Connect the AC output power cable (using a five-core cable as an example).
To avoid damaging the rubber liner, do not route a cable with a crimped OT terminal directly
through it.
It is recommended that the length of the PE cable to be stripped be 15 mm longer than the
length of other cables.
The cable colors in figures are for reference only. Select appropriate cables according to the
local standards.

Other manuals for Huawei SUN2000-30KTL-M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-30KTL-M3 and is the answer not in the manual?

Huawei SUN2000-30KTL-M3 Specifications

General IconGeneral
ModelSUN2000-30KTL-M3
Max. DC Input Voltage1100 V
Number of MPPTs3
Rated AC Output Power30000 W
Max. Output Current47.8 A
Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)< 3%
Max. Efficiency98.7%
European Weighted Efficiency98.4%
DC ConnectionMC4
Protection DegreeIP66
Cooling MethodNatural convection
MPPT Voltage Range200 V - 1000 V
Max. AC Output Power33000 W
Rated AC Voltage400 V
AC Voltage Range320 V - 480 V
DisplayLED Indicators
CommunicationRS485, WLAN
Operating Temperature Range-25°C to 60°C
Relative Humidity0% - 100%
Operating Altitude4000 m
Weight43 kg
Dimensions640 x 530 x 270 mm
Max. DC Input Power45000 Wp