Before turning on the AC switch between the solar inverter and the power grid, check that the 
AC voltage is within the specified range using a multimeter set to the AC position.
•
If the solar inverter is connected to an LG battery, turn on the DC switch within 1 minute after 
turning on the AC switch. If you turn on the DC switch after more than 1 minute, the solar 
inverter will shut down and start again.
1. If a battery is connected, turn on the battery switch.
2. Turn on the AC switch between the solar inverter and the power grid.
3. (Optional) Remove the screw for locking the DC switch. 
4. Turn on the DC switch (if any) between the PV string and the solar inverter.
5. Turn on the DC switch at the bottom of the solar inverter.
6. Observe the LED indicators to check the operating status of the solar inverter.
5
Powering On the System
for 1s and then Off for 1s; 
Blinking at short Intervals: 
0.2s and then Off for 0.2s)
The solar inverter is operating in grid
Blinking green 
at long 
intervals
The DC is on and the AC is off.
Blinking green 
at long 
intervals
Blinking green at 
long intervals
Both the DC and AC are on, and the solar 
inverter is not exporting power to the 
power grid.
Blinking green at 
long intervals
The DC is off and the AC is on.
Both the DC and AC are off.
Blinking red at 
short intervals
There is a DC environmental alarm, such 
as an alarm indicating that High String 
Input Voltage, String Reverse Connection, 
or Low Insulation Resistance.
Blinking red at 
short intervals
There is an AC environmental alarm, such 
as an alarm indicating Grid