● The battery voltage may result in serious injury. Use dedicated insulation tools
when connecting cables.
● Ensure that cables are correctly connected between the battery terminals and
the SUN2000 battery terminals.
Cables with high rigidity, such as armored cables, are not recommended as battery
cables, because poor contact may be caused by the bending of the cables.
Figure 5-16 Preparing cord end terminals for the PV cable and routing them into
the SUN2000 maintenance compartment
(1) Cord end terminal
(2) Crimping tool (3) Route the cable terminals
through the battery cable
holes.
Step 2 Locate the SUN2000 battery terminal in the tting bag.
Step 3 Insert the crimped cable terminals into the positive and negative battery terminals
on the SUN2000.
Connect the cable terminals and tighten the screws. Pull the battery cables back
to check that they are securely connected.
SUN2000-4.95KTL-JPL1
User Manual 5 Electrical Connections