EasyManuals Logo

Huawei SUN2000-5KTL-M1 User Manual

Huawei SUN2000-5KTL-M1
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
Symbol Description
Indicates a potentially hazardous situation which, if not
avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
Notice is used to address practices not related to personal
injury.
Supplements the important information in the main text.
NOTE is used to address information not related to personal
injury, equipment damage, and environment deterioration.
Change History
Changes between document issues are cumulative. The latest document issue
contains all the changes made in earlier issues.
Issue 17 (2024-01-12)
Updated 5.2 Installation Preparation.
Updated 5.8.2 Connecting the RS485 Communications Cable (Smart Power
Sensor).
Updated 8.3 Troubleshooting.
Updated 10.1 SUN2000 Technical Specications10.1 SUN2000 Technical
Specications.
Updated A Grid Code.
Issue 16 (2023-11-02)
Updated 5.4 Connecting the AC Output Power Cable.
Issue 15 (2023-09-30)
Updated 7.2.1.4 Capacity Control.
Issue 14 (2023-09-06)
Updated A Grid Code.
Issue 13 (2023-08-23)
Updated D Rapid Shutdown.
Issue 12 (2023-07-30)
Updated About This Document.
Updated 2.1 Product Introduction.
SUN2000-(3KTL-10KTL)-M1 Series
User Manual About This Document
Issue 17 (2024-01-12) Copyright © Huawei Technologies Co., Ltd. iv

Table of Contents

Other manuals for Huawei SUN2000-5KTL-M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-5KTL-M1 and is the answer not in the manual?

Huawei SUN2000-5KTL-M1 Specifications

General IconGeneral
Max. Efficiency98.4%
Rated AC Output Power5000 W
Max. Apparent Power5500 VA
Max. DC Input Voltage1100 V
Number of MPPTs2
Operating Temperature Range-25°C to +60°C
Start Voltage200 V
European Efficiency97.8%
Protection DegreeIP65
Start-up Voltage200 V
Output Voltage Range180 V - 280 V
Frequency Range50 Hz / 60 Hz
Power Factor0.8 leading ... 0.8 lagging
THD<3%
Cooling MethodNatural Convection
Max. DC Power7500 W
Rated AC Voltage230 V

Related product manuals