    caroline99Sep 12, 2025
    What causes String Reverse Connection on Huawei SUN2000-8KTL-M2?
    • G
      Gregory RodriguezSep 12, 2025
      If your Huawei Inverter reports a 'String Reverse Connection' error, it means the PV string polarity is reversed. To correct this, check if the PV string is reversely connected to the SUN2000. If it is, wait until the PV string current decreases below 0.5 A, set the DC SWITCH to OFF, and then adjust the PV string polarity.
  • S
    Sheri WilliamsAug 25, 2025
    What to do if Huawei SUN2000-8KTL-M2 Inverter shows Grid Loss?
    • N
      nguyenwilliamAug 25, 2025
      If your Huawei Inverter indicates a 'Grid Loss' error, it means the power grid might be experiencing an outage, or the AC power cable could be disconnected, or the AC circuit breaker is OFF. To resolve this, first, verify that the AC voltage is normal. Second, ensure that the AC power cable is properly connected and the AC switch is in the ON position.
  • D
    Dennis WolfAug 25, 2025
    How to fix Low Insulation Resistance on Huawei Inverter?
    • Y
      ywoodAug 26, 2025
      If your Huawei Inverter displays a 'Low Insulation Resistance' error, it could be due to the PV array being short-circuited to ground or the power cable not being well insulated, especially in a moist environment. Here's what you should do: * Check the impedance between the PV array output and PE, and eliminate any short circuits or points of poor insulation. * Ensure the PE cable for the inverter is correctly connected. * If you're certain the impedance is less than the preset protection threshold in cloudy or rainy conditions, you can log in to the mobile app, SmartLogger, or NMS to reset the insulation impedance protection threshold.
  • M
    Mark OdonnellSep 23, 2025
    How to troubleshoot Abnormal PV Module Configuration on Huawei Inverter?
    • R
      Richard FordSep 23, 2025
      If your Huawei Inverter reports 'Abnormal PV Module Configuration,' it means the PV module configuration doesn't meet requirements, or the PV module output is reversely connected or short-circuited. Check whether the total number of PV modules, the number of PV modules in a string, and the number of PV strings meet requirements, and verify that the PV module output isn't reversely connected.
  • C
    cmorrisonSep 12, 2025
    Why does my Huawei SUN2000-8KTL-M2 display Output Overcurrent?
    • D
      Danny WilsonSep 12, 2025
      If your Huawei Inverter is showing an 'Output Overcurrent' error, it indicates that the grid voltage has dropped dramatically or the power grid is short-circuited, causing the inverter's transient output current to exceed the upper threshold and triggering protection. The inverter monitors its external working conditions in real time and will automatically recover once the fault is rectified. If the alarm occurs frequently and affects the power production, check whether the output is short-circuited. If the problem continues, contact your dealer or Huawei technical support.
  • L
    Lisa DiazSep 16, 2025
    What does Abnormal Residual Current mean on Huawei SUN2000-8KTL-M2 Inverter?
    • P
      Peter TaylorSep 16, 2025
      If your Huawei Inverter is showing an 'Abnormal Residual Current' error, it indicates that the input-to-ground insulation impedance has decreased during the inverter operation. To address this: 1. If the alarm occurs accidentally, the external power cable may be temporarily abnormal. The inverter will automatically recover once the fault is rectified. 2. If the alarm occurs frequently or persists, check that the impedance between the PV string and ground is not below the lower threshold.
  • M
    Manuel RodriguezSep 4, 2025
    What does Output DC Component Overhigh mean on my Huawei SUN2000-8KTL-M2 and how to resolve it?
    • S
      shannon89Sep 5, 2025
      If your Huawei Inverter displays an 'Output DC Component Overhigh' error, it indicates that the DC component of the output current exceeds the specified upper threshold. The SUN2000 detects its external working conditions in real time and automatically recovers after the fault is rectified. If the alarm occurs frequently, contact your dealer or Huawei technical support.
  • E
    egomezSep 5, 2025
    What causes Transient AC Overvoltage on a Huawei SUN2000-8KTL-M2 Inverter and how can I fix it?
    • O
      odonaldsonSep 5, 2025
      If your Huawei Inverter reports a 'Transient AC Overvoltage' error, it means the inverter has detected that the phase voltage exceeds the transient AC overvoltage protection threshold. 1. Check if the grid connection voltage exceeds the upper threshold. If yes, contact the local power operator. 2. If you have confirmed that the grid-tied voltage exceeds the upper threshold and have obtained the consent of the local power operator, modify the overvoltage protection threshold through the mobile phone app, SmartLogger, or NMS. 3. Check whether the peak power grid voltage exceeds the upper threshold.
  • K
    Keith ParkerDec 1, 2025
    What does Grid Overvoltage mean on my Huawei Inverter and how can I fix it?
    • L
      Larry RobinsonDec 1, 2025
      If your Huawei SUN2000 Inverter is showing a 'Grid Overvoltage' error, it means the power grid voltage is beyond the upper threshold or the overvoltage duration exceeds the value specified by HVRT. Here's what you can do: 1. If the alarm occurs occasionally, the power grid may be temporarily abnormal. The SUN2000 automatically recovers after detecting that the power grid becomes normal. 2. If the alarm occurs frequently, check whether the grid voltage is within the acceptable range. If not, contact the local power operator. If yes, log in to the mobile phone app, SmartLogger, or NMS to modify the grid overvoltage protection threshold with the consent of the local power operator. 3. Check whether the peak voltage of the power grid is too high. If the fault persists and cannot be rectifi...
  • J
    James WilliamsonAug 29, 2025
    What causes String Current Backfeed on a Huawei SUN2000-8KTL-M2 and how to resolve it?
    • Z
      zmorganAug 30, 2025
      If your Huawei Inverter reports 'String Current Backfeed,' it means that too few PV modules are connected in series, causing the end voltage to be lower than other PV strings. To resolve this: 1. Check if the number of PV modules connected in series is less than that of other PV strings. If so, wait until the PV string current drops below 0.5 A, set the DC SWITCH to OFF, and adjust the number of PV modules. 2. Check if the PV string is shaded. 3. Check if the open-circuit voltage of the PV string is normal.

Huawei SUN2000-8KTL-M2 Specifications

General IconGeneral
Rated Output Power8 kW
Max. DC Voltage1100 V
Start Voltage200 V
Rated DC Voltage600 V
Number of MPP Trackers2
Max. Input Current per MPPT13 A
Max. Short-Circuit Current per MPPT15 A
Rated AC Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)< 3%
Protection ClassIP65
Operating Temperature Range-25 °C to +60 °C
CoolingNatural convection
Efficiency Max.98.6%
Max. Apparent AC Power8, 800 VA
Rated AC Voltage230 V
DC Injection Current< 0.5 mA
Relative Humidity0% - 100%
Operating AltitudeUp to 4000 m
DisplayLED Indicators
CommunicationRS485
Warranty5 years (Standard), 10 years (Optional)