SUN2000-(12KTL, 15KTL, 17KTL, 20KTL)-M0
User Manual
Issue
03
Date
2019-07-19
HUAWEI TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Huawei SUN2000-8KTL-M0

Questions and Answers

  • K
    katelyn25Sep 12, 2025
    What causes String Reverse Connection on Huawei SUN2000-8KTL-M0 Inverter?
    • M
      Mary MooreSep 12, 2025
      If your Huawei Inverter reports a 'String Reverse Connection' error, it means the PV string polarity is reversed. To correct this, check if the PV string is reversely connected to the SUN2000. If it is, wait until the PV string current decreases below 0.5 A, set the DC SWITCH to OFF, and then adjust the PV string polarity.
  • J
    Jennifer CrossAug 25, 2025
    What to do if Huawei SUN2000-8KTL-M0 shows Grid Loss?
    • S
      Shawn SimonAug 25, 2025
      If your Huawei Inverter indicates a 'Grid Loss' error, it means the power grid might be experiencing an outage, or the AC power cable could be disconnected, or the AC circuit breaker is OFF. To resolve this, first, verify that the AC voltage is normal. Second, ensure that the AC power cable is properly connected and the AC switch is in the ON position.
  • E
    Eric Lawson Jr.Aug 25, 2025
    How to fix Low Insulation Resistance on Huawei SUN2000-8KTL-M0?
    • A
      ashleyrubioAug 26, 2025
      If your Huawei Inverter displays a 'Low Insulation Resistance' error, it could be due to the PV array being short-circuited to ground or the power cable not being well insulated, especially in a moist environment. Here's what you should do: * Check the impedance between the PV array output and PE, and eliminate any short circuits or points of poor insulation. * Ensure the PE cable for the inverter is correctly connected. * If you're certain the impedance is less than the preset protection threshold in cloudy or rainy conditions, you can log in to the mobile app, SmartLogger, or NMS to reset the insulation impedance protection threshold.
  • F
    fthorntonSep 23, 2025
    How to troubleshoot Abnormal PV Module Configuration on Huawei Inverter?
    • J
      Jennifer LeachSep 23, 2025
      If your Huawei Inverter reports 'Abnormal PV Module Configuration,' it means the PV module configuration doesn't meet requirements, or the PV module output is reversely connected or short-circuited. Check whether the total number of PV modules, the number of PV modules in a string, and the number of PV strings meet requirements, and verify that the PV module output isn't reversely connected.
  • A
    Ashley HoustonSep 12, 2025
    Why does my Huawei SUN2000-8KTL-M0 Inverter display Output Overcurrent?
    • M
      Michael GibsonSep 12, 2025
      If your Huawei Inverter is showing an 'Output Overcurrent' error, it indicates that the grid voltage has dropped dramatically or the power grid is short-circuited, causing the inverter's transient output current to exceed the upper threshold and triggering protection. The inverter monitors its external working conditions in real time and will automatically recover once the fault is rectified. If the alarm occurs frequently and affects the power production, check whether the output is short-circuited. If the problem continues, contact your dealer or Huawei technical support.
  • C
    cshermanSep 16, 2025
    What does Abnormal Residual Current mean on Huawei SUN2000-8KTL-M0 Inverter?
    • T
      Thomas AndrewsSep 16, 2025
      If your Huawei Inverter is showing an 'Abnormal Residual Current' error, it indicates that the input-to-ground insulation impedance has decreased during the inverter operation. To address this: 1. If the alarm occurs accidentally, the external power cable may be temporarily abnormal. The inverter will automatically recover once the fault is rectified. 2. If the alarm occurs frequently or persists, check that the impedance between the PV string and ground is not below the lower threshold.
  • K
    Karen SextonSep 4, 2025
    What does Output DC Component Overhigh mean on my Huawei Inverter and how to resolve it?
    • K
      Kevin SnyderSep 5, 2025
      If your Huawei Inverter displays an 'Output DC Component Overhigh' error, it indicates that the DC component of the output current exceeds the specified upper threshold. The SUN2000 detects its external working conditions in real time and automatically recovers after the fault is rectified. If the alarm occurs frequently, contact your dealer or Huawei technical support.
  • E
    Elizabeth Wright DVMSep 5, 2025
    What causes Transient AC Overvoltage on a Huawei SUN2000-8KTL-M0 and how can I fix it?
    • M
      Megan DavisSep 5, 2025
      If your Huawei Inverter reports a 'Transient AC Overvoltage' error, it means the inverter has detected that the phase voltage exceeds the transient AC overvoltage protection threshold. 1. Check if the grid connection voltage exceeds the upper threshold. If yes, contact the local power operator. 2. If you have confirmed that the grid-tied voltage exceeds the upper threshold and have obtained the consent of the local power operator, modify the overvoltage protection threshold through the mobile phone app, SmartLogger, or NMS. 3. Check whether the peak power grid voltage exceeds the upper threshold.
  • N
    nmunozDec 1, 2025
    What does Grid Overvoltage mean on my Huawei SUN2000-8KTL-M0 and how can I fix it?
    • W
      williambergDec 1, 2025
      If your Huawei SUN2000 Inverter is showing a 'Grid Overvoltage' error, it means the power grid voltage is beyond the upper threshold or the overvoltage duration exceeds the value specified by HVRT. Here's what you can do: 1. If the alarm occurs occasionally, the power grid may be temporarily abnormal. The SUN2000 automatically recovers after detecting that the power grid becomes normal. 2. If the alarm occurs frequently, check whether the grid voltage is within the acceptable range. If not, contact the local power operator. If yes, log in to the mobile phone app, SmartLogger, or NMS to modify the grid overvoltage protection threshold with the consent of the local power operator. 3. Check whether the peak voltage of the power grid is too high. If the fault persists and cannot be rectifi...
  • J
    John ThompsonAug 29, 2025
    What causes String Current Backfeed on a Huawei SUN2000-8KTL-M0 and how to resolve it?
    • V
      Victoria HallAug 29, 2025
      If your Huawei Inverter reports 'String Current Backfeed,' it means that too few PV modules are connected in series, causing the end voltage to be lower than other PV strings. To resolve this: 1. Check if the number of PV modules connected in series is less than that of other PV strings. If so, wait until the PV string current drops below 0.5 A, set the DC SWITCH to OFF, and adjust the number of PV modules. 2. Check if the PV string is shaded. 3. Check if the open-circuit voltage of the PV string is normal.

Huawei SUN2000-8KTL-M0 Specifications

General IconGeneral
ModelSUN2000-8KTL-M0
Rated Output Power8000 W
Max. DC Voltage1100 V
Maximum DC Input Voltage1100 V
Start Voltage200 V
Number of MPPTs2
Rated Grid Frequency50 Hz / 60 Hz
Max Efficiency98.6%
Weight17 kg
Cooling MethodNatural Convection
Protection DegreeIP65
Protection ClassClass I
CoolingNatural Convection
Protection LevelIP65
Max. AC Power8800 VA
Maximum AC Output Power8800 VA
Rated AC Voltage220 V / 380 V, 230 V / 400 V
Rated Grid Voltage220 Vac / 380 Vac, 230 Vac / 400 Vac
AC Voltage Range180-280 V
Dimensions (W x H x D)525 x 470 x 262 mm
Operating Temperature Range-25°C to +60°C
Max. DC Power12000 W
Maximum DC Input Power12000 W