SUN2000-(12KTL, 15KTL, 17KTL, 20KTL)-M0 
User Manual 
 
Copyright © Huawei Technologies Co., Ltd. 
 
Figure 5-19 SmartLogger networking 
 
 
 
In the SmartLogger1000A networking scenario, the Smart Dongle cannot be connected. 
 
A maximum of 80 devices can connect to a single SmartLogger1000A, such as inverters, Smart 
Power sensor, and EMI. You are advised to connect fewer than 30 devices to each RS485 route. 
 
The Smart Power Sensor is a necessary export limitation. Select the Smart Power Sensor according 
to the actual project. 
 
To ensure the system response speed, the Smart Power Sensor is recommended to be connected to a 
COM port separately from inverter COM port. 
 
5.6.1 Connecting the RS485 Communications Cable (Inverter 
Cascading) 
Procedure 
Step 1  Connect the signal cable to the signal cable connector.