WA603DE & WA653DE
Fat AP Configuration Guide 3 Service Configuration
Issue 02 (2012-04-19) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
9
Parameter Description
Internal Heater If you select Enable Internal Heater, the PoE IN port of the
WA653DE is enabled to connect the PoE switch or power module to
provide power for the device.
If the device type is WA603DE, the 10/100/1000 PoE port is enabled.
By default, Enable Internal Heater is deselected.
PoE OUT Port If you select Enable 'PoE OUT' Port, the PoE OUT port of the
WA653DE is enabled to provide power for other devices in PoE
mode.
This parameter is available for only the WA653DE.
By default, the Enable 'PoE OUT' Port option is deselected. Do not
select this option unless you are required to do so.
Temperature
Update
Interval for automatically updating the temperature information.
The value ranges from 30 to 7200 seconds. The default value is 30
seconds.
3. Click Update Settings to save the settings.
----End
3.1.2 (Optional) Changing the User Name and Password
The default user name is super and password is sp-admin. To ensure access security, perform
the following operations to change the default user name and password after the first login:
1. Choose Configuration > Device from the left navigation tree, and set the parameters in the
Service Provider Login area according to Table 3-2.
Figure 3-2 Changing the user name and password
Table 3-2 Description of user-specific parameters
Parameter Description
UserName Enter a new user name. The name is a string of up to 32 characters,
including letters, digits, and symbols.
Current Password Enter the current password.