WARNING: Risk of Electric Shock.
Install only to an residual-current device
(RCD) when connecting the power supply to
the power outlet. Applicable to USA/Canada.
If power supply is installed outdoors: Risk of
Electric Shock. Install only to a covered
Class A GFCI receptacle (RCD) that has an
enclosure that is weatherproof with the
attachment plug cap inserted or removed.
CAUTION: Do not make new holes in
the charging station plate.
CAUTION: Do not put your feet on the
baseplate of the charging station.
WARNING: The power supply cable
and extension cable must be outside the
work area to avoid damage to the cables.
When connecting the power supply, only use a power
outlet that is connected to an residual-current device
(RCD).
1. Read and understand the instructions about where
to put the charging station. Refer to
To examine
where to put the charging station on page 14
.
2. Put the charging station in the selected area.
Note:
Do not attach the charging station with the
screws to the ground until the guide wire is
installed. Refer to
To install the guide wire on page
21
.
3. Connect the low-voltage cable to the charging
station.
4. Put the power supply at a minimum height of 30
cm / 12 in.
5. Connect the power supply cable to a 100-240V
power outlet.
Note:
When the charging station is connected, it
is possible to charge the product. Place the
product in the charging station while the boundary
and guide wires are being laid. Switch on the
product. Refer to
Main switch on page 31
. Do not
continue with any product settings before the
installation is complete.
6. Put the low-voltage cable in the ground with stakes
or bury the cable. Refer to
To put the wire into
position with stakes on page 21
or
To bury the
boundary wire or the guide wire on page 21
.
7. Connect the wires to the charging station after the
installation of boundary wire and guide wire is
complete. Refer to
To install the boundary wire on
page 20
and
To install the guide wire on page
21
.
8. Attach the charging station to the ground with the
supplied screws after the guide wire is installed.
Refer to
To install the guide wire on page 21
.
3.5.3 To install the boundary wire
CAUTION: Do not put remaining wire in
a coil. The coil causes interference with the
product.
1. Put the boundary wire around all of the work area.
Start and complete the installation behind the
charging station.
2. Open the connector and put the boundary wire in
the connector.
3. Close the connector with a pair of pliers.
4. Cut the boundary wire 1-2 cm / 0.4-0.8 in. above
each connector.
5. Push the right connector onto the metal pin on the
charging station with the mark "AR".
6. Push the left connector onto the metal pin on the
charging station with the mark "AL".
20