Ref: REFLEX/SCANFLEX MANUAL
EDITION 1: JULY ’97 9
Analogue Output - is connected :- Screen to terminal 24 *
Positive +ve to terminal 25 *
Negative -ve to terminal 26 *
* Gives an indication of only one point at time. For continuous analogue output an Analogue
Output Module SA-10 is required.
Separate Temperature Compensation - when compensation is provided by a separate
temperature sensor on each point then the controller should be connected to the Multiplexor
SM-10 with a shielded twisted pair and connected:-
Screen to terminal 21) terminal Shld ) On
Core* to terminal 22) On Controller terminal + ) Multiplexor
Core* to terminal 23) terminal - )
* The polarity of the cores is unimportant.
Communications between Scanflex Modules Via RS485
The Controller is connected to the Multiplexor Module, Analogue Module and Relay Module
using 2 core screened cable. TB5 terminals 35 to 37, on the Controller top PCB are connected
to the matching SHLD, -ve and +ve terminals on TB1 on the Multiplexor and then looped on to
TB1 on the Analogue and/or Relay Modules used in the system. For location of terminals see
Pages 8, 60, 63 and 66.
Communications to external PC or PLC via RS232
Communications from the Controller via RS232 to Hycontrol's vision system or to the user's
external devices, is via 3 core screened cable connected to terminals 31 to 34 on TB5.
MULTIPLEXOR MODULE SM-10 - ELECTRICAL CONNECTIONS See Page 60
Communication - From the Controller terminals 35-37 to the Multiplexor is via a 2 core
screened cable connected to TB1. Use Belden 8451 or equivalent cable.
Power Supply - Selectable 110V or 230V AC +10/-15%, 50Hz or 60Hz, 12VA
is connected to TB4. Voltage selector SW4 must be set to the
correct voltage.
Transducer link to Co-axial cable RG62AU must be used. Connect to TB3 TRANS
Controller Core to HOT
Screen to SCR
Transducer connection
to Multiplexor - Up to 10 transducers can be connected to one Multiplexor. If
fewer than 10 transducers are connected and called up in the
programme they must be connected to Points 1 to 'n' in sequence.
NO GAPS MUST BE LEFT IN THE RANGE PROGRAMMED.
(e.g. 6 transducers must be connected to
Points 1 to Point 6).
RXV15 Transducer Blue to HOT
Black & Screen to SCR
RXM19 Transducer Core to HOT
Screen to SCR
RXM19ER Transducer Core to HOT
Screen to SCR
HOT