INSTALLATION
NETWORK CONNECTIVITY REQUIREMENTS
The recommended way to connect to the network is to access 4G wireless communication or a Wi-Fi module
integrated in the charger. A SIM card meeting local networking requirements is required. Make sure the local
signal strength is strong and stable; otherwise a signal amplier must be installed.
If there is no local 3G/4G communication signal, a standard wired internet connection is available. Wired
connections must meet the following requirements:
RJ45 Ethernet
Network cable type: 5e class or greater, 8P plus PE, shielding wire.
It is recommended that the line length is less than 75m. Greater than 75m length requires a customised
engineering solution.
Minimum bandwidth required:
Upstream: 128 kbps
Downstream: 4 Mbps
Demand connection reliability: 99.9%.
For special congurations, please contact us.