-16-
SPECIFICATIONS
Model
A5/32
A7/32
A10/32
A13/32
Air temperature: 15°C DB/12°C WB, water inlet/outlet temperature: 26°C/28°C
Heating capacity
kW
3.30
4.80
7.10
9.13
Power input
kW
0.71
1.06
1.48
1.96
COP
4.65
4.53
4.80
4.66
Air temperature: 26°C DB/23.5°C WB, water inlet/outlet temperature: 26°C/28°C
Heating capacity
kW
4.50
6.60
9.60
12.50
Power input
kW
0.95
1.39
1.85
2.06
COP
4.74
4.75
5.19
6.06
Power supply
220 - 240V~, 1Ph, 50Hz
Max power input
kW
1.36
1.88
2.41
2.69
Max current
A
6.31
8.52
10.73
12.23
Setting temperature range
15°C - 40°C
Running temperature range
5°C - 43°C
Refrigerant type/charged
R32/0.55kg
R32/0.65kg
R32/0.8kg
R32/1.1kg
Compressor
Brand
GMCC
Landa
Input
kW
0.790
0.975
1.425
1.720
Air side heat-exchanger
Hydrophilic aluminum & Inner groove copper tube
Fan motor
Fan type
Axial
Fan size
mm
Φ427×139
Φ427×139
Φ522×140
Φ522×140
Motor output
W
32
32
60
60
Motor input
W
80
80
150
150
Water side heat exchanger
Titanium heat-exchanger with PVC casing
Advised water flow
m³/h
2.0
3.0
5.0
8.0
Net dimension (L×D×H)
mm
816×307×553
913×367×718
Packing dimension (L×D×H)
mm
885×360×670
1,010×450×851
Net weight
kg
37
40
47
54
Gross weight
kg
41
46
53
60
Noise level (@10m)
dB(A)
26
28
28
29