EasyManua.ls Logo

Hydro-Smart 115 - Error Code Fault Analysis Continued

Hydro-Smart 115
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Warranty
36Page
RedLED Remote
Malfunction
description
Diagnosis
Six
Times
51
AbnormalGas
SolenoidValve
Check
f
or connection/breakage of wires (Part #708)
and/or burn marks on the computer board (Part
#701).
Six
Times
55
AbnormalMain
GasValve
Check forconnection/breakageofwires(Part#708)
and/orburnmarksonthecomputerboard(Part
#701).
Four
Times
61
FanMotorFault
Check forconnection/breakageofwires,dustbuildup
inthefanmotor(Part#103)and/orburnmarksonthe
computerboard(Part#701).
Checkforfrozen/corrosionofconnectors(Part#103).
One
Time
70
Computerboard
Fault
Check for connection/breakage of wires (Part #714)
and/or burn marks on the computer board (Part
#701).
Checkthepowersupplyofthewaterheater.
SixTimes 72
FalseFlame
Detection
Forindoormodels,checkifcondensatedrainis
installedonthevent collarofthewaterheater.
Checkifthereisleakingfromheatexchanger(Part
#401).
N/A 74
Miscommunication
betweenWater
heaterandremote
controller
Checkthemodeltypeoftheremotecontroller.
Inspect the connections between the water heater
andremotecontroller.
Checkthepowersupplyofthewaterheater.
Five
Times
99
Imperfect
combustion
Checkthegastypeofthewaterheater.
Inspecttheenvironmentaroundthewaterheater.
Determinehowlongtheunithasbeeninstalled.
Checkthealtitude/elevationoftheareaofwherethe
waterheaterinstalled.
Checkifthereisanyblockageintheintakeairand/or
exhaust.
Ifthewaterheateris installed asadirectventsystem,
checkwhetherthereisenoughdistancebetweenthe
intakeairterminalandtheexhaustterminal.
Checkifthereisgreaseand/ordirtintheburner(Part
#101)andthefanmotor(Part#104),especiallyifthe
waterheaterhasbeeninstalledinacontaminated
area.