12. Technical Specification
Technical data C01KIT - C45KIT
Type C01
KIT
C02
KIT
C06
KIT
C10
KIT
C17
KIT
C30
KIT
C45
KIT
Steam output [kg/h] 1 2 6 10 17 30 45
Power supply * 230V/1/N 400V/3/N 50-60Hz
Power
Usage [kW] 0,75 1,5 4,5 7,5 12,8 22,5 33,8
Input [A] 3,3 6,5 6,5 10,8 18,4 32,5 48,8
Circuit Protection [A]*** 1x6 1x10 3x10 3x16 3x25 3x35 3x63
Control L3
Control voltage 230 V
Steam hose connection [mm] 1x25 1x25 1x25 1x25 1x25 1x40 1x40
Condensate hose connection [mm] 1x9 1x9 1x9 1x12 1x12 1x12 2x12
empty weight [kg] 4,5 5 7 8 11 12 15
operating weight [kg] 6 7 12 15 29 30 60
dimensions heigh [mm] 320 300 344 390 575 575 667
width [mm] 252 252 252 252 328 328 330
depth [mm] 175 195 175 175 254 254 316
Water Installation
100 x 10
3
to 100 x 10
4
pascal with 3/4" connection for external
thread
fan unit** VG08 VG08 VG08 VG08 VG17 VG30 2xVG30
airflow capacity [m³/h] 160 160 160 160 185 350 2x350
* Other voltages on request.
** Not included with delivery.
*** Multiply power input by 1.3 after full blow-down. Note overload capacity of automatic breakers. If necessary, select the next higher rat-
ing.