Pump Factory Settings
Hydraulic
Pump
Pressure Limit
3200 psi (220 bar)
Cut Pressure
Set Point
Factory Set to Minimum Pressure for Startup.
Adjust per startup operating instructions in this manual.
Pierce
Pressure
Set Point
Factory Set to Minimum Pressure for Startup.
Adjust per startup operating instruction in this manual.
Utility Hook-Ups (located at rear of pump)
Cooling In
1 NPT Female
Cooling Out
1 NPT Female
Cutting Water
In
3/4 NPT Female
Drain Water
Out
3/4 NPT Female
Cutting Water
Out
3/8 HP Female 9/16 HP Female
Warnings and Shutdowns
Intensifier HP
Leak Warning
Warning
Intensifier
Over Cycle
Shutdown
Inlet Cutting
Water Under
Pressure
P < 40 psi (2.8 bar) Shutdown
Hydraulic Oil
Level Low
Shutdown
Hydraulic Oil
Temp.
Alert Temp
T > 131°F (55°C) Warning
Hydraulic Oil
Temp.
Shutdown
Temp
T > 150°F (65°C) Shutdown
Motor Fault
Shutdown
59