MAINTENANCE
3-24
Service Manual
Air coming 
out of torch?
To 
page 3-25
From
page 3-23
Pilot arc 
fires ?
Press & hold GAS TEST switch S2. 
Adjust pressure regulator for 70 psi 
(4.8 bar) indication (dynamic) on 
gauge.
Check control board TP2 
for 12V when torch start 
switch is pressed.
Unplug power supply. Disconnect 
control board connector JP8. 
Measure resistance between JP8 
sockets 5 & 6 while pressing torch 
start switch.
Disconnect torch lead and check pins 
6 & 7 of torch lead plug when torch 
start button is pressed.
0 ohms ?
Yes
Indicates 0 psi 
?
Check JP4 sockets and control 
board pins 5 & 6. Check wires 
W65 & W66. Check gas 
solenoid V1 & pressure 
regulator. If no problems are 
found replace control PCB.
70 psi (4.8 bar)
dynamic ?
No Yes
Check regulator & 
hoses for leaks.
Ensure GAS TEST switch S2 has 
been released. Press torch start 
switch to fire pilot arc.
Yes
Yes
Check regulator & 
hoses for leaks.
No
No
Yes
12V?
Relay CR2 
closes when 
torch start 
switch is 
pressed
 ?
0 ohms ?
See Torch 
Check Start 
Circuit later in 
this section.
Check JP4 sockets
and control board 
pins 1 & 2. 
Check wires W61 & 
W62.
Check pilot arc relay 
CR2.
Repair or replace as 
needed.
Yes
No
See Torch 
Check Start 
Circuit later 
in this 
section.
Check wiring from power 
supply quick disconnect 
to control board JP8.
No
No
Yes
No
NoYes
Wiring 
OK?
See Torch 
Check Start 
Circuit later 
in this 
section.
Yes
Repair wiring 
as needed.
No
Check 
consumables and 
replace nozzle, if 
necessary.
Yes
9-96