Fault
code
Description Power
LED
Fault
LED
Fault
icon
Solutions
0-21 Gas flow lost while
cutting
On On • Restore the gas inlet pressure and restart the power
supply.
• Check the torch lead for leaks or kinking.
0-22 No gas input On On • Connect the gas source and restart the power
supply.
0-30 Torch consumables stuck
This indicates either a
“torch stuck open” or
a “torch stuck closed”
situation.
On On
• If the consumables became loose or were removed
while the power supply is ON, turn OFF the power
supply, correct the problem and then turn ON the
power supply to clear this fault.
• If the consumables appear to be installed
correctly, the torch may be damaged. Contact your
Hypertherm distributor or authorized repair facility.
0-40 Over/under temperature On On • Leave the power supply on to allow the fan to cool
the power supply.
• If the internal temperature of the power supply
approaches -22°F (-30°C), movethe power supply
to a warmer location.

Table of Contents

Other manuals for Hypertherm powermax65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm powermax65 and is the answer not in the manual?

Hypertherm powermax65 Specifications

General IconGeneral
BrandHypertherm
Modelpowermax65
CategoryWelding System
LanguageEnglish

Related product manuals