SpecificationS
powermax
65/85
 Operator Manual  1-7
1
 Defined as a plot of output voltage versus output current.
2
 Equipment complies with IEC 61000-3-12 provided that the short-circuit power S
sc
 is greater than or equal to 
2035KVA at the interface point between the user’s supply and the public system. It is the responsibility of the installer 
or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the 
equipment is connected only to a supply with a short-circuit power S
sc 
greater than or equal to 2035 KVA.
3
 Equipment complies with IEC 61000-3-11 provided that the supply impedance, Zmax, is 0.201 or less. It is the 
responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator 
if necessary, that the equipment is connected only to a supply with a impedance of 0.201 or less.
4
 WARNING: This Class A equipment is not intended for use in residential locations where the electrical power is 
provided by the public low-voltage supply system. There may be potential difficulties in ensuring electromagnetic 
compatibility in those locations, due to conducted as well as radiated disturbances.