SpecificationS
powermax
65/85
Operator Manual 1-9
1
Defined as a plot of output voltage versus output current.
2
Equipment complies with IEC 61000-3-12 provided that the short-circuit power S
sc
is greater than or equal to
2035KVA at the interface point between the user’s supply and the public system. It is the responsibility of the installer
or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power S
sc
greater than or equal to 2035 KVA.
3
Equipment complies with IEC 61000-3-11 provided that the supply impedance, Zmax, is 0.201 or less. It is the
responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator
if necessary, that the equipment is connected only to a supply with a impedance of 0.201 or less.
4
WARNING: This Class A equipment is not intended for use in residential locations where the electrical power is
provided by the public low-voltage supply system. There may be potential difficulties in ensuring electromagnetic
compatibility in those locations, due to conducted as well as radiated disturbances.

Table of Contents

Other manuals for Hypertherm powermax65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm powermax65 and is the answer not in the manual?

Hypertherm powermax65 Specifications

General IconGeneral
BrandHypertherm
Modelpowermax65
CategoryWelding System
LanguageEnglish

Related product manuals