EasyManua.ls Logo

Hytera HR106X - Post-installation Check

Hytera HR106X
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
If the repeater is installed in outdoor environments with frequent
thunderstorms, such as the top of
mountains or buildings, you must install an external lightning protection module (optional) on the network
interface.
3. Connect the antenna, feed line, ground cable, and power cord to the repeater.
You must purchase the antenna and feed lines separately.
You must prepare a ground cable.
The repeater can be connected to the AC power supply and the battery simultaneously
. In such case,
the AC power supply powers the repeater and also charges the battery; when the AC power s
upply
malfunctions, the battery works as a UPS battery to power the repeater.
4. Ground the repeater through the ground screw located on the rear panel.
3.4 Post-installation Check
To check whether the repeater works properly, do as follows:
1.
Turn the repeater on.
2.
Observe the LED indicators and the display in the front panel.
If the repeater works properly, the power supply indicator on the float charging board glows yellow or blue,
and the display shows the current channel.
If not, the power supply indicator glows red, and the display shows the alarm code.
For details, refer to 4.4 Checking the Status.