Alarm Information
User Guide
16
In this case, the repeater fails to work.
When the repeater detects the invalid level, the repeater restarts and returns to the normal state.
The repeater restarts every time the level changes.
7.7.2 Solution
Contact your dealer for technical support.
7.8 Low Forward Power Alarm
7.8.1 Description
When the repeater detects that the TX power is below the preset value of forward power, the alarm indicator glows
red and the LED displays "Eb".
When the TX power is 0 W, the repeater stops transmission.
7.8.2 Solution
Check whether the RF adapter cable, antenna, or feed line is properly connected.
If yes, contact your dealer for technical support.
If no, re-connect or replace the cable, antenna, or feed line.
7.9 Network IP Conflict Alarm
7.9.1 Description
When the IP address of the repeater conflicts with that of other devices in the same network segment, the alarm
indicator glows red and the LED displays "H3".
In this case, network services of the repeater are unavailable.
7.9.2 Solution
Check and modify the network configuration.