LITHIUM SERIES® Electric Torque Tool (BTM and BTM-DOC Models) Operations Manual
36
TIGHTENING THE HYTORC NUT
NOTE: The HYTORC Nut inner sleeve is tightened in a counter clockwise direction (left hand threads).
• Power on the tool, adjust tool settings and set the fastener type to HYTORC Nut.
• Position the tool over the nut.
• Pull the trigger to apply torque until the tool stalls at the specified torque
• If a Release Angle has been specified continue holding the trigger and the tool will restart and then stall again after
completing the Release. Then the tool can be released from the nut.
• Release the trigger after the tool has completed all specified operations.
• The status light turns amber during operation. If the operation is successful, the status light will turn green, if
unsuccessful the status light will turn red.
• If the Beeper is enabled the tool will provide an audible beep upon completion of the operations.
• Should torque be applied without a release angle the tool may lock onto the nut. If this happens set the tool to loosen to
free the tool and repeat the tighten operation.
(CONT’D.)