Chapter 6. Symptom-to-FRU Index 99
1406
Presence test error
1. Run Enhanced Diagnostics
14XX
Not listed above. Check printer before
replacing system board
1. Printer
2. System Board
15XX 1. SDLC Adapter
1692
Boot sequence error
1. Run FDISK to ensure at least one active
partition is set active
16XX 1. 36/38 Workstation Adapter
1762
Hard disk drive configuration error
1. Run Configuration. (See “Setup Utility
program” on page 10.)
1780 (Disk Drive 0)
1781 (Disk Drive 1)
1782 (Disk Drive 2)
1783 (Disk Drive 3)
1. Hard Disk Drive
2. System Board
3. Riser card
4. Hard Disk Cable
5. Power Supply
180X, 188X
PCI configuration or resource error
1. Run Setup and verify PCI/ISA
configuration settings.
2. If necessary, set ISA adapters to Not
available to allow PCI adapters to properly
configure.
3. Remove any suspect ISA adapters.
4. Rerun diagnostics.
5. PCI Adapter
1962
Boot sequence error
1. Possible hard disk drive problem; see
“Hard disk drive boot error” on page 72.
209X 1. Diskette Drive
2. Diskette Cable
20XX
Not listed above
1. BSC Adapter
21XX 1. SCSI Device
2. 16-bit AT Fast SCSU adapter
3. Alternate BSC adapter
2401, 2402
If screen colors change
1. Display
2401, 2402
If screen colors are OK
1. System Board
2. Display
2409 1. Display
2410 1. System Board
2. Display
2462
Video memory configuration error
1. Check cable connections
2. Run Setup and verify video configuration
settings
3. Video Memory Modules
4. Video Adapter (if installed)
5. System Board
4611, 4630 1. Multiport/2 Interface Board
2. Multiport/2 Adapter
POST Error Code FRU/Action