6 IBM : Hardware Maintenance Manual
Physical specification — small desktop model
Dimensions
Height: 88 mm (3.4 in.)
Width: 305 mm (12.0 in.)
Depth: 380 mm (14.9 in.)
Weight
Minimum configuration as shipped: 8.5 kg (18 lb)
Maximum configuration: 8.6 kg (19 lb)
Environment
Air temperature:
System on: 10° to 35° C (50° to 95° F)
System off: 10° to 43° C (50° to 110° F)
Maximum altitude: 2134 m (7000 ft)
Note: The maximum altitude, 2134 m (7000 ft),
is the maximum altitude at which the
specified air temperatures apply. At
higher altitudes, the maximum air
temperatures are lower than those
specified.
Humidity:
System on: 8% to 80%
System off: 8% to 80%
Electrical input
Input voltage:
Low range:
Minimum: 90 V ac
Maximum: 137 V ac
Input frequency range: 57–63 Hz
Voltage switch setting: 115 V ac
High range:
Minimum: 180 V ac
Maximum: 265 V ac
Input frequency range: 47–53 Hz
Voltage switch setting: 230 V ac
Input kilovolt-amperes (kVA) (approximate):
Minimum configuration as shipped: 0.08 kVA
Maximum configuration: 0.30 kVA
Note: Power consumption and heat output vary
depending on the number and type of
optional features installed and the power-
management optional features in use.
Heat output (approximate) in British thermal units (Btu)
per hour:
Minimum configuration: 205 Btu/hr (60 watts)
Maximum configuration: 375 Btu/hr (120 watts)
Airflow
Approximately 0.25 cubic meters per minute (9 cubic
feet per minute) maximum
Acoustical noise-emission values
Average sound-pressure levels:
At operator position:
Idle: 38 dBA
Operating: 43 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 33 dBA
Operating: 37 dBA
Declared (upper limit) sound-power levels:
Idle: 3.75 bels
Operating: 4.99 bels
Note: These levels were measured in controlled
acoustical environments according to the
procedures specified by the American
National Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in accordance
with ISO 9296. Actual sound-pressure levels
in a given location might exceed the average
values stated because of room reflections and
other nearby noise sources. The declared
sound-power levels indicate an upper limit,
below which a large number of computers
will operate.
Note: The computer is classified as a Class A or
Class B digital device. See the Quick Reference
for further information about this
classification.

Table of Contents

Other manuals for IBM 6339

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 6339 and is the answer not in the manual?

IBM 6339 Specifications

General IconGeneral
BrandIBM
Model6339
CategoryDesktop
LanguageEnglish

Related product manuals