X'040600'
•
X'040B00'
X'040600' Unit/Module Width Specified Is Not Supported
Explanation: The unit/module width specified in the Write Bar Code Data
Descriptor field is not supported.
Alte rn a te Ex c e p tion Actio n : Use closest smaller width supported or the device
default for those devices with only one fixed default value.
X'040700' Element Height Specified Is Not Supported
Explanation: The element height specified in the Write Bar Code Data Descriptor
field is not supported.
Alte rn a te Ex c e p tion Actio n : Use closest height supported.
X'040800' Height Multiplier Specified Is Not Supported
Explanation: The height multiplier specified in the Write Bar Code Data
Descriptor field is not supported.
Alte rn a te Ex c e p tion Actio n : Use closest multiplier supported.
X'040900' Wide/Narrow Ratio Is Not Supported
Explanation: The wide/narrow ratio specified in the Write Bar Code Data
Descriptor field is not supported.
Alte rn a te Ex c e p tion Actio n : Use the printer default wide element width. The
default wide element width and the specified or default unit/module width should
be such that a wide/narrow ratio of 2.50 or 3.00 results.
X'040A00' Invalid SymbolReference Point
Explanation: The symbol reference point given in the Write Bar Code command
is not a valid or supported value.
Alte rn a te Ex c e p tion Actio n : None.
X'040B00' Invalid Bar Code Modifier
Explanation: The bar code modifier, byte 17 of the Bar Code Data Descriptor
structured field, is not a valid or supported value for the bar code type specified
by byte 16 of the same structured field.
Alte rn a te Ex c e p tion Actio n : None.
Appendix A. IPDS Exception Reporting Codes 143