Environmental specifications
The environmental specifications for the RackSwitch G8052 are listed in the
following table.
Table 8. Environmental specifications
Specification Measurement
Temperature, ambient operating C to +40° C (32° to 104° F)
Temperature (fan failure), operating C to +35° C (32° to 95° F)
Temperature, storage -40° C to +85° C (-40° to 185° F)
Relative humidity (non-condensing),
operating
10 to 90%
Relative humidity (non-condensing), storage 10 to 90%
Altitude, operating 3,050 m (10,000 feet)
Altitude, storage 12,190 m (40,000 feet)
Acoustic noise Less than 65dB
Heat dissipation 444 BTU/hour (typical)
Power specifications
The power specifications for the RackSwitch G8052 are listed in the following table.
Table 9. AC power specifications
Specification Measurement
Number of power supplies 2 (1+1 load sharing/redundant)
AC-input frequency (universal) 50 - 60 Hz
AC-input voltage (universal) 100-240 VAC
AC inrush current 15 A
AC-input current (typical) 1.1 A (RMS) @ 120 V
0.6 A (RMS) @ 230 V
AC-input current (maximum) 1.7 A (RMS) @ 120 V
0.9 A (RMS) @ 230 V
Power supply rated output power 450 W each
System power dissipation (typical) 130 W
System power dissipation (maximum) 200 W
DC-output current 10.0 A (typical)
Chapter 1. Introduction 11