3. In the main menu, enter the machine-type model (MTM) number for the
replacement switch. For example:
/boot/mtm 1455-48E
where 1455-48E is the MTM of the unit that is being replaced
4. Enter the serial number for the replacement switch. For example:
/boot/esn 1000001
where 1000001 is the serial number of the unit that is being replaced.
5. Reset the switch using the following command:
/boot/reset
6. When prompted to confirm the reset, enter y. The switch reboots.
7. After the switch reboots, at the command prompt, verify that the VPD
information is correct by issuing the show sys-info command using the ISCLI
interface or the /info/sys/general command using MenuCLI interface.
ISCLI interface output example:
show sys-info
System Information at 13:41:04 Fri Jan 20, 2011
Time zone: America/US/Pacific
Daylight Savings Time Status: Disabled
IBM System Networking RackSwitch G8052
Switch has been up for 0 days, 17 hours, 10 minutes and 45 seconds.
Last boot: 20:41:01 Thu Jan 19, 2011 (power cycle)
MAC address: fc:cf:62:9d:2b:00 IP (If 1) address: 0.0.0.0
Management Port MAC Address: fc:cf:62:9d:2b:fe
Management Port IP Address (if 128): 203.203.21.2
Hardware Revision: 0
Hardware Part No: BAC-000*a*00
Switch Serial No: US7C45t78
Manufacturing date:
Software Version 6.6.0 (FLASH image1), active configuration.
Temperature Mother Top: 34 C
Temperature Mother Bottom: 38 C
Temperature Daughter Top: 35 C
Temperature Daughter Bottom: 37 C
Warning at 70 C and Recover at 100 C
Fan 1 in Module 1: RPM=17647 PWM=255(100%) Front-To-Back
Fan 2 in Module 1: RPM= 9310 PWM=255(100%) Front-To-Back
Fan 3 in Module 2: RPM=17419 PWM=255(100%) Front-To-Back
Fan 4 in Module 2: RPM= 9326 PWM=255(100%) Front-To-Back
Fan 5 in Module 3: RPM=17197 PWM=255(100%) Front-To-Back
Fan 6 in Module 3: RPM= 9523 PWM=255(100%) Front-To-Back
Fan 7 in Module 4: RPM=17252 PWM=255(100%) Front-To-Back
Fan 8 in Module 4: RPM= 9490 PWM=255(100%) Front-To-Back
System Fan Airflow: Front-To-Back
Power Supply 1: Vin Fault
Power Supply 2: OK
Or
MenuCLI interface output example:
/info/sys/general
44 IBM System Networking RackSwitch G8052: Installation Guide