Table 14. Critical information checklist (continued)
Checked? Data Notes
Notes regarding supportshow
output
Information about the new chassis
New factory serial number
New serial number (if available)
2. Open a telnet session and log into the device as admin. The default password is password. Enable
the logging function on your telnet or serial console connection.
3. Back up the current conguration by entering the configUpload -all. Enter the requested
information at the prompts.
Note: If you are using the Virtual Fabric feature, run configupload -vf before running the
configupload command to save the logical switch conguration.
This configUpload -all command uploads the device conguration to the customer-dened FTP
server, making it available for downloading. Alternatively, you can save the conguration le to a USB
device. For more information about this command, refer to the Fabric OS Command Reference.
switch:admin> configupload
Protocol (scp or ftp) [ftp]: ftp
Server Name or IP Address [host]: 123.123.123.123
User Name [user]: Admin24
File Name [config.txt]: config-switch0.txt
Password:
Upload complete
switch:admin>
4. Record the WWN value: Enter wwn, and then copy the command output into a le named cong-
miscinfo.txt.
switch:admin> wwn
10:00:00:60:69:00:00:0a
5. Enter ipAddrShow -sw, and then copy the command output into the cong-miscinfo.txt le.
switch:admin> ipaddrshow -sw
SWITCH
Ethernet IP Address: 14.25.60.14
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 14.25.60.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 14.25.43.1
CP1
Ethernet IP Address: 14.25.50.13
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 14.25.43.1
Backplane IP address of CP0 : 14.11.0.6
Backplane IP address of CP1 : 14.11.0.7
switch:admin>switch:admin>
6. Display and record the manufacturer serial numbers.
Enter chassisShow, and then copy the command output into the cong-miscinfo.txt le.
72
IBM Storage Networking SAN64B-6: SAN64B-6 Installation, Service, and User Guide

Table of Contents

Other manuals for IBM SAN64B-6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN64B-6 and is the answer not in the manual?

IBM SAN64B-6 Specifications

General IconGeneral
BrandIBM
ModelSAN64B-6
CategorySwitch
LanguageEnglish

Related product manuals