EasyManuals Logo
Home>IBM>Controller>ServeRAID M5014

IBM ServeRAID M5014 User Manual

IBM ServeRAID M5014
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
6-2 Using the ServeRAID M5000 Series Battery Assembly
6.1 Monitoring the Battery Backup with the MegaRAID
Configuration Utilities
This section describes the MegaRAID configuration utilities you can use
to monitor the condition of the installed ServeRAID M5000 Series Battery
Assembly and to change the automatic learn mode options. They include
the WebBIOS Configuration Utility, MegaCLI, and MegaRAID Storage
Manager.
6.1.1 Monitoring the ServeRAID M5000 Series Battery Assembly with
the WebBIOS Configuration Utility
The WebBIOS CU is a web-based utility for configuring and managing
RAID volumes. Its operation is independent of the operating system
because the utility resides in the MegaRAID BIOS. Follow these steps to
monitor the status of an installed battery assembly with the WebBIOS
utility:
1. Boot the system.
2. Start the WebBIOS CU by pressing CTRL+H when the prompt
appears on the screen during boot-up.
The WebBIOS CU main menu screen appears.
3. Click Controller Properties on the WebBIOS CU main menu
screen.
The first Controller Properties screen appears, as shown in the
following figure.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM ServeRAID M5014 and is the answer not in the manual?

IBM ServeRAID M5014 Specifications

General IconGeneral
BrandIBM
ModelServeRAID M5014
CategoryController
LanguageEnglish

Related product manuals