6-6 Using the ServeRAID M5000 Series Battery Assembly
6.1.2 Monitoring the ServeRAID M5000 Series Battery Assembly with
the MegaCLI Utility
You can use the MegaCLI commands in this section to monitor the
battery assembly and to select the settings for battery backup unit
(BBU)-related options.
6.1.2.1 Display BBU Information
Use the command in Table 6.1 to display complete information about the
BBU for the selected controller(s).
6.1.2.2 Display BBU Status Information
Use the command in Table 6.2 to display complete information about the
status of the BBU, such as temperature and voltage, for the selected
controller(s).
Table 6.1 Display BBU Information
Convention MegaCli -AdpBbuCmd -aN|-a0,1,2|-aALL
Description Displays complete information about the BBU, such as status, capacity information,
design information, and properties.
Table 6.2 Display BBU Status Information
Convention MegaCli -AdpBbuCmd -GetBbuStatus –aN|-a0,1,2|-aALL