Replacing the ServeRAID M5000 Series Battery Assembly 6-13
6.1.3.3 Starting a Learn Cycle Manually
To start the learn cycle properties manually, perform the following steps:
1. Click the Physical tab to open the physical view.
2. Select the BBU icon in the left panel.
3. Click the Operations tab.
The BBU operations appear.
4. Click Start Learn Cycle and then click Go.
Another method to use the BBU operations is to right-click the BBU icon
to open the operations menu and select Start Learn Cycle.
6.2 Replacing the ServeRAID M5000 Series Battery
Assembly
For optimal performance, replace the ServeRAID M5000 Series Battery
Assembly every three years.
When you install a new battery assembly, the battery recharge cycle
counter for the battery assembly is automatically set to zero. For
instructions on installing the battery assembly, see Section 5.1, “Installing
the ServerRAID M5000 Series Battery Assembly on a Controller.”
CAUTION:
The battery is a lithium ion battery and can present a fire or chemical burn
hazard if mistreated. Do not dissassemble, heat above 100 °C (212 °F), or
incinerate. To avoid possible explosion, do not burn. Keep away from
children. Exchange only with the IBM-approved part. Recycle or discard
the battery as instructed by local regulations. In the United States, IBM has
a process for the collection of this battery. For information, call 1-800-426-
4333. Have the IBM part number for the battery unit available when you
call. (C007)