Features and operating specifications
Table 1 contains a summary of the features and operating specifications of the
DS3300. Depending on your DS3300 model, some features might not be available,
or some specifications might not apply.
Table 1. Features and operating specifications
General:
v Modular components
High-capacity disk drives
RAID controller modules
Power supplies with built-in fan
units
v Technology
Supports disk array technology
iSCSI host interface, redundant
data storage, power and cooling
system, and SAS disk
controllers
Hot-swap technology for hard
disk drives, power supplies, and
controllers
v User interface
Built-in power, activity, and fault
LEDs, identification labeling on
components, rear LEDs, and
connectors
Easy-to-replace hard disk drives,
power supplies with built-in fan
units, and controllers
Hard disk drive storage:
Maximum hard disk drives per
DS3300: 12
Drive type: SAS and SATA
Controllers:
v Technology and interfaces:
iSCSI interface: Two RJ-45
gigabit Ethernet connectors per
controller
SAS interface: One 26-pin,
mini-SAS connectors per
controller
Acoustical noise emissions:
For maximum system configurations
(12 hard disk drives installed)
v Sound power (idling): 6.2 bels
v Sound power (operating): 6.2 bels
v Sound pressure (idling): 48 dBA
v Sound pressure (operating): 48
dBA
AC power supply with built-in fan:
v The DS3300 comes with two
hot-swap 530-watt (115 - 230 V
ac) power supplies.
v The two power supplies provide
redundant power to the DS3300.
Size:
v Height: 8.7 cm (3.4 in.)
v Depth: 52.1 cm (20.5 in.)
v Width: 44.7 cm (17.6 in.)
v Weight: approximately 17.2 kg
(38.0 lb) for a standard unit; when
fully configured, 29.3 kg
(64.6 lb)
Environment:
v Air temperature:
DS3300 on: 10° to 35°C (50°
to 95°F); altitude: 30.5 (100 ft)
below to 3000 m (9840 ft)
above sea level; temperature
change: 10°C (18°F) per hour
DS3300 off: 10° to 50°C (14.0°
to 120.0°F); maximum altitude:
3000 m (9840 ft); temperature
change: 15°C (27.0°F) per hour
v Humidity:
DS3300 on: 20% to 80%
DS3300 off: 10% to 90%
Maximum dew point: 26°C
(79°F)
Maximum humidity gradient:
10% per hour
Heat output
Approximate heat output in British
thermal units (Btu) per hour:
v Minimum configuration: 205 Btu
(60 watts)
v Maximum configuration 1235
Btu (361 watts)
Electrical input:
v Sine-wave input (50 - 60 Hz)
required
v Input voltage low range:
Minimum: 90 V ac
Maximum: 136 V ac
v Input voltage high range:
Minimum: 198 V ac
Maximum: 264 V ac
v Approximate input kilovolt-amperes
(kVA):
Minimum: 0.06 kVA
Maximum: 0.38 kVA
Notes:
1. Power consumption and heat
output vary depending on the
number and type of optional
features that are installed and the
power-management optional
features that are in use.
2. These levels were measured in
controlled acoustical environments
according to the procedures
specified by the American National
Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in
accordance with ISO 9296. Actual
sound-pressure levels in a given
location might exceed the average
stated values because of room
reflections and other nearby noise
sources. The declared sound-power
levels indicate an upper limit, below
which a large number of computers
will operate.
4 System Storage DS3300 Storage Subsystem: Installation, User’s, and Maintenance Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System Storage DS3300 and is the answer not in the manual?

IBM System Storage DS3300 Specifications

General IconGeneral
BrandIBM
ModelSystem Storage DS3300
CategoryStorage
LanguageEnglish

Related product manuals