21
Electrical Requirements
Voltage
The maximum allowable voltage variation is ±10% of the
rated voltage on the ice machine model/serial number
plate at start-up (when the electrical load is highest).
Fuse/Circuit Breaker
A separate fuse/circuit breaker must be provided for each
ice machine.
Total Circuit Ampacity
The total circuit ampacity is used to help select the wire
size of the electrical supply.
The wire size (or gauge) is also dependent upon location,
materials used, length of run, etc., so it must be
determined by a qualified electrician.
Electrical Specifications
Air-cooled Ice Machine
Ice Machine
Voltage Phase
Cycle
Min. Fuse/
Circuit Breaker
WU-0100 115/1/60 15
IC-0170 115/1/60 15
115/1/60
15
NOTE: Model/serial plate information overrides
all data listed in this chart.
IU-0170
IC-0220 115/1/60 15
115/1/60
15IU-0220