CLEANING THE CONDENSER
A dirty condenser restricts airflow, resulting in excessively
high operating temperatures. This reduces ice production
and shortens component life. Clean the condenser at least
every six months. Follow the steps below.
1. The washable filter on self-contained ice machines is
designed to catch dust, dirt, lint and grease. This helps
keep the condenser clean. Clean the filter with a mild
soap and water solution.
2. Clean the outside of the condenser with a soft brush
or a vacuum with a brush attachment. Clean from top
to bottom, not side to side. Be careful not to bend the
condenser fins.
3. Shine a flashlight through the condenser to check for
dirt between the fins. If dirt remains: Blow
compressed air through the condenser fins from the
inside. Be careful not to bend the fan blades.
4. Use a commercial condenser coil cleaner. Follow the
directions and cautions supplied with the cleaner.
5. Straighten any bent condenser fins with a fin comb.
6. Carefully wipe off the fan blades and motor with
a soft cloth. Do not bend the fan blades. If the fan
blades are excessively dirty, wash with warm, soapy
water and rinse thoroughly.