4 - 2
4-2 PLL ADJUSTMENTS
REFERENCE
FREQUENCY
LPL-A LOCK
VOLTAGE
VCO-A LOCK
VOLTAGE
1LO-A
OUTPUT
LEVEL
LPL-B LOCK
VOLTAGE
VCO-B LOCK
VOLTAGE
1LO-B
OUTPUT
LEVEL
3LO
OUTPUT
LEVEL
S3LO
OUTPUT
LEVEL
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT LOCATION UNIT ADJUST
1
2
1
1
2
3
4
1
1
1
2
3
4
1
1
1
Display frequency: Any
Turn L52 on the PLL unit to 4 rota-
tion downside for presetting.
Receiving
Display frequency: 0.030000 MHz
Mode : USB
Receiving
Display frequency
: 14.999999 MHz
Mode : USB
Receiving
Display frequency
: 19.999999 MHz
Mode : USB
Receiving
Display frequency
: 44.999999 MHz
Mode : USB
Receiving
Display frequency
: 60.000000 MHz
Mode : USB
Receiving
Display frequency
:
0.030000 MHz, 7.999999 MHz
8.000000 MHz, 19.999999 MHz
20.000000 MHz, 44.999999 MHz
45.000000 MHz, 60.000000 MHz
Receiving
Sub display freq. : 0.030000 MHz
Mode : USB
Receiving
Sub display freq.
: 7.999999 MHz
Mode : USB
Receiving
Sub display freq.
: 19.999999 MHz
Mode : USB
Receiving
Display frequency
: 44.999999 MHz
Mode : USB
Receiving
Display frequency
: 60.000000 MHz
Mode : USB
Receiving
Sub display freq.
:
0.030000 MHz, 7.999999 MHz
8.000000 MHz, 19.999999 MHz
20.000000 MHz, 44.999999 MHz
45.000000 MHz, 60.000000 MHz
Receiving
Display frequency
: Any
Receiving
Display frequency
: Any
Receiving
PLL
PLL
PLL
PLL
PLL
PLL
PLL
PLL
PLL
Connect a frequency
counter to check
point P81.
Connect an RF volt-
meter to check point
P81.
Connect a digital
multimeter or oscillo-
scope to check point
LPA.
Connect a digital
multimeter or oscillo-
scope to check point
LVA.
Connect an RF volt-
meter to check point
P351.
Connect a digital
multimeter or oscillo-
scope to check point
LPB.
Connect a digital
multimeter or oscillo-
scope to check point
LVB.
Connect an RF volt-
meter to check point
P651.
Connect an RF volt-
meter to check point
P701.
Connect an RF volt-
meter to check point
P801.
64.000000 MHz
Maximum level
(0 dB or more)
2.0 V
4.3 V
4.3 V
4.3 V
4.3 V
0 dBm or more
2.0 V
4.3 V
4.3 V
4.3 V
4.3 V
0 dBm or more
16 dBm or more
7 dBm or more
PLL
PLL
PLL
PLL
PLL
L52
(R33
for critical
adjustment)
L81, L82
C154
C278
C258
C228
C208
Verify
C454
C578
C558
C528
C508
Verify
Verify