ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
LOADING REFERENCE
VOLTAGE
• Display: "13.8 SET"
• Receiving
Set the power supply voltage to
13.8 V.
Push [F-5].
(A beep sounds,
and then another
beeps sound
0.5 sec. later)
SETTING ID REFERENCE
LEVEL
1 • Display: "ID HF+1.0A"
• Transmitting
Connect a 50
Ω
dummy loads
to [ANT1], [144MHz ANT] and
[430MHz ANT].
Push [F-5].
2 • Display: "ID VHF+1.0A"
• Transmitting
3 • Display: "ID UHF+1.0A"
• Transmitting
4 • Display: "IPD HF+1.0A"
• Transmitting
5 • Display: "IPD V/UHF+1.0A"
• Transmitting
4-8 ADJUSTMENTS ON THE FUNCTION DISPLAY
1) Connect the short plug (Page 4-1) to [REMOTE], and while holding down [MENU] and [SSB], turn ON the power.
2) The main adjustment menu appears.
¤
ID ADJUSTMENTS
¤
MAIN
ADJUSTMENT MENU
ID TX REF RX OPT
ADJ
Select the ID adjustment (See below)
Select the transmit adjustment (Page 4-13) Select the reference frequency/APC reference adjustment (Page 4-17)
Select the receive adjustment (Page 4-18)
MENU
13.8 SET
SET
ID
Reterns to the previous screen.
Stores the value and move to the next item.
4 - 11
NOTE: If the optional UX-9100 is installed, remove it before the adjustment.