ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
PREPARATION
–
• Connect an SSG to [ANT1], and
then set it as;
Frequency : 14.1515 MHz
Modulation
: None
Level
†
:
+20 dBu (–87 dBm)
–– –
TOTAL GAIN 1 • Display:
"Total Gain HF POFF"
• Receiving
– – – Push [F-5].
(Beeps sound
20–30 sec. later)
2 • Display:
"Total Gain HF PON"
• Receiving
–––
EXTERNAL AGC 3 • Display: "AGC (HF)"
• Receiving
• Set the SSG as;
Level
†
:
+70 dBu (–37 dBm)
– – Push [F-5].
(Beeps sound
40 sec. later)
S-METER NOTE: DO NOT change the output level of the SSG until the beeps sound.
4 • Display: "S0 Level HF"
• Receiving
• Set the SSG as;
Level : OFF
– – Push [F-5].
(Beep sounds,
and then
another beeps
sound
0.5 sec. later)
5 • Display: "S9 Level HF"
• Receiving
• Set the SSG as;
Level
†
:
+34 dBu (–73 dBm)
Push [F-5].
(Beep sounds,
and then
another beeps
sound
1 sec. later)
6 • Display: "S9+60 Level HF"
• Receiving
• Set the SSG as;
Level
†
:
+90 dBu (–17 dBm)
Automatically returns to the receive adjustment menu.
¤
RECEIVE ADJUSTMENTS
• RECEIVE ADJUSTMENTS (HF band)
• Receive adjustment menu.
MENU
HF VHF UHF
RX
Reterns to the previous screen.
Stores the value and move to the next item.
Starts the receive adjustments (HF band).
(See below)
Starts the receive adjustments (VHF).
(Page 4-19)
Starts the transmit adjustments (UHF).
(Page 4-20)
4 - 18
†
; The output level of the standard signal generator (SSG) is indicated as the SSG’s terminated circuit.