ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
REFERENCE
FREQUENCY
1 – • Connect a frequency counter
to [430MHz ANT], through an
attenuator.
–– –
2 • Display: "REF OSC"
• Transmitting
• Push [F-5]. (Automatically starts
to transmit.)
[430MHz
ANT]
[MAIN DIAL] 440.000000
MHz (±30 Hz)
Push [F-5].
Automatically returns to the reference adjustment menu.
Push [MENU] to return to the main adjustment menu (Page 4-6).
¤
REFERENCE ADJUSTMENTS
• APC REFERENCE ADJUSTMENT
• REFERENCE FREQUENCY ADJUSTMENT
• Reference adjustment menu.
ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
ID APC VERIFICATION • Display: "IdAPC Check"
• Transmitting
• Push [F-5]. (Automatically starts
to transmit.)
– – Push [F-5].
(Beeps sound
1 sec. later)
Automatically returns to the reference adjustment menu.
Push [MENU] to return to the main adjustment menu (Page 4-6).
MENU
REF APC VCC
REF
Reterns to the previous screen.
Stores the value and move to the next item
Select the reference frequency adjustment.
Select the APC reference adjustment.
MENU
REF
REF
OSC
SET
Reterns to the previous screen.
Stores the value and move to the next item.
MENU
APC
IdAPC
Check
SET
Reterns to the previous screen.
Stores the value and move to the next item.
4 - 17