ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
PREPARATION
Connect an AG and millivoltmeter
to [MIC], and then set it as;
Frequency : 1.5 kHz
Level : 1 mV
Connect a power meter to
[144MHz ANT].
––
TUNED BPF 1 • Display: "Tuned BPF"
• Receiving
Push [F-5]. (Automatically starts
to transmit.)
Push [F-5].
2 • Display: "Tuned BPF 1-1"
• Transmitting
Push [F-5].
(A beep sounds,
and then
another beeps
sound 3 sec.
later)
3* • Display: "Tuned BPF 1-2"
• Transmitting
4 • Display: "Tuned BPF 2-1"
• Transmitting
5 • Display: "Tuned BPF 2-2"
• Transmitting
6 • Display: "Tuned BPF 3-1"
• Transmitting
7 • Display: "Tuned BPF 3-2"
• Transmitting
8 • Display: "Tuned BPF 4-1"
• Transmitting
9 • Display: "Tuned BPF 4-2"
• Transmitting
10 • Display: "Tuned BPF 5-1"
• Transmitting
11 • Display: "Tuned BPF 5-2"
• Transmitting
TX TOTAL GAIN 12 • Display: "Total Gain VHF"
• Receiving
Push [F-5]. (Automatically starts
to transmit.)
[144MHz
ANT]
[MAIN DIAL] 50 W
Push [F-5].
TX POWER & POWER
METER SETTING
13 • Display: "POWER VHF"
• Receiving
Push [F-5]. (Automatically starts
to transmit.)
Push [F-5].
14 • Display: "POWER VHF Min"
• Transmitting
[144MHz
ANT]
[MAIN DIAL] 1.5 W
Push [F-5].
15 • Display: "POWER VHF 10%"
• Transmitting
10 W
Push [F-5].
16 • Display: "POWER VHF 50%"
• Transmitting
50 W
Push [F-5].
17 • Display: "POWER VHF 75%"
• Transmitting
75 W
Push [F-5].
18 • Display:
"POWER VHF 100%"
• Transmitting
100 W
Push [F-5].
POWER DOWN SETTING 19
• Display: "POWER Down VHF"
• Transmitting
Push [F-5]. (Automatically starts
to transmit.)
[144MHz
ANT]
[MAIN DIAL] 50 W
Push [F-5].
TRANSMIT ADJUSTMENTS (VHF band)
*: For RF-B UNIT adjustment (Page 4-8), set the value to "8A," using [MAIN DIAL].