EasyManua.ls Logo

Icom IC-9100 - Page 41

Icom IC-9100
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
TX POWER
(1.2 GHz BAND)
20 • Display: "POWER 1.2G"
• Receiving
Push [F-5]. (Automatically starts
to transmit.)
"FORV"
on the
display.
[MAIN DIAL] 2.600 V
Push [F-5].
21 • Display:
"TX Total Gain 1.2G"
• Transmitting
1) Connect a spectrum analyzer to
the pin 2 of J6002, and then set
it as;
Center : 10.95 MHz
Span : 100 kHz
RBW : 3 kHz
VBW : 100 Hz
2) Set the AG and millivoltmeter
as;
Frequency : 1.5 kHz
Level : 1 mV
Pin 2 of
J6002
(MAIN
UNIT)
[MAIN DIAL] –32.0 dBm
(±0.1 dB)
Push [F-5].
ALC METER 22 • Display: "ALC VHF"
• Transmitting
Set the AG as;
Frequency : 1.5 kHz
Level : 10 mV
Push [F-5].
(A beep sounds,
and then another
beeps sound
3 sec. later)
DRIVE GAIN 23 • Display: "DRIVE VHF"
• Transmitting
Push [F-5].
SWR METER 24 • Display: "SWR VHF-1"
• Transmitting
Push [F-5].
25 • Display: "SWR VHF-2"
• Transmitting
Connect a 25
Ω
dummy load to
[144MHz ANT].
Push [F-5].
Automatically returns to the transmit adjustment menu.
4 - 15
THE LOCATION OF CHECK POINT ON THE MAIN UNIT
TRANSMIT ADJUSTMENTS (VHF band) (continued)
“1R2TIF” line
C141
143
EP6030
EP6031
EP6032
EP6033
EP6034
8
J6002
J6002
R141
143
J1002
TO UX-9100 J3
7

Other manuals for Icom IC-9100